Model | SUN-5K -SG01LP1-US | | SUN-6K -SG01LP1-US | | SUN-7.6K -SG01LP1-US/EU | SUN-8K -SG01LP1-US/EU |
Battery Input Data | |
Battery Type | Lead-acid or Lithium-ion |
Battery Voltage Range (V) | 40-60 | |
Max. Charging Current (A) | 120 | 135 | 190 | 190 |
Max. Discharging Current (A) | 120 | 135 | 190 | 190 |
External Temperature Sensor | Yes | |
Charging Curve | 3 Stages / Equalization |
Charging Strategy for Li-Ion Battery | Self-adaption to BMS10400 |
PV String Input Data |
Max. DC Input Power (W) |
Rated PV Input Voltage (V) | 370 (125-500) |
Start-up Voltage (V) | 125 |
MPPT Voltage Range (V) | 150-425 | |
Full Load DC Voltage Range (V)PV Input Current (A) | 300-425 | 200-425 |
13+13 | 26+13 | 26+26 |
Max. PV ISC(A) | 22+22 | 44+22 | 44+44 |
No.of MPP Trackers 2 |
No.of Strings per MPP Tracker | | 1+1 2+1 2+25000 6000 7600 8000 5500 6600 8360 8800 20.8/24 25/28.8 31.7/36.5 34.5/33 33.3/38.5 36.4/34.8 22.9/26.4 27.5/31.7 34.8/40.2 38/36.3 36.7/42.3 40/38.3 |
AC Output Data |
Rated AC Output Active Power (W) |
Max AC Output Active Power (W) |
AC Output Rated Current (A) |
Max AC Output Current (A) |
Max. Continuous AC Passthrough (A) 50 |
Peak Power (off grid) | 2 time of rated power, 10 S |
Power Factor Adjustment Range | 0.8 leading to 0.8 lagging |
Power Factor | 1 |
Output Frequency and Voltage | 50 / 60Hz; L1/L2/N(PE) 120/240Vac (split phase), 208Vac (2/3 phase), L/N/PE 220/230Vac (single phase) |
Grid Type | Split Phase; 2/3 phase; Single Phase |
Total Harmonic Distortion (THD) | <3% (of nominal power) |
DC Current Injection | <0.5% In |
Efficiency | |
Max. Efficiency | 97.60% |
Euro Efficiency | 97.00% |
MPPT Efficiency Protection | 99.90% | |
| Anti-islanding Protection, PV String Input Reverse Polarity Protection, |
Integrated Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, |
| Output Shorted Protection, Surge Protection |
Over Voltage Category | DC Type II/AC Type III | |
Certifications and Standards | |
Grid Regulation | VDE4105, IEC61727/62116, VDE0126, AS4777.2, CEI 0 21, EN50549- 1, G98, G99, C10- 11, UNE217002, NBR16149/NBR16150 |
Safety EMC / Standard | IEC/EN 61000-6- 1/2/3/4, IEC/EN 62109- 1, IEC/EN 62109-2 |
General Data | |
Operating Temperature Range (C) | -40-60℃, >45℃ Derating |
Cooling | Smart Cooling |
Noise (dB) | ≤30 dB |
Communication with BMS | RS485; CAN |
Weight (kg) | 32 |
Cabinet Size (WxHxD mm) | 420×670×233 (Excluding Connectors and Brackets) |
Protection Degree | IP65 |
Installation Style | Wall-mounted |
Warranty | 5 Years (10 Years Optional) |